Part Number Hot Search : 
HCF40107 LC74770 BLY90 1S922 RS106 PT23101 SLA50 DEVICES
Product Description
Full Text Search
 

To Download PMC-12V060W1NA Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  technical d at asheet pmc panel mount power supply 12v 60w 1 phase , nec class 2 / pmc - 12v060w1na all parameters are specified at 25 c ambient unless otherwise noted. www. deltapsu .com ( june 2013 , rev. 0 0) 1 pm c highlights & features ? universal ac input voltage without power de - rating ? full corrosion resistant aluminium chassis ? nec class 2 power supply and limited power source (lps ) approvals ? high mtbf > 700,000 hrs. as per telcordia sr - 332 ? wide operating temperature range from -20 c to 70 c ? conformal coating (class i, div 2 hazardous locations ready) safety standards cb certified for worldwide use model number: pmc - 12v060w1na unit weight : 0.2 8 kg dimensions (l x w x d): 128 x 97 x 38 mm general description the new pmc panel mount power supply is the latest offering from one of the world?s largest power supply manufacturers and so lution providers - delta. the product offers a nominal output voltage of 12v, 60w output power ranging with nec class 2 power suppl y and limited power source (lps) approvals. the pmc - 12v060w1na comes with a wide temperature range from - 20c to +70c and conformal coating on pcba (class i, div 2 hazardous locations ready) to protect against chemical and dust pollutants. delta?s panel m ount power supply also offers overvoltage and overload protection. using a wide input voltage range design, it is compatible worldwide. the input also includes dc operating voltage from 125 - 375vdc. best of all, this excellent design and quality does not co me with a big price tag . model information pm c panel mount power supply model number input v oltage range output v oltage output cur r ent pmc - 12v060w1na 85- 264 vac (12 5 -37 5 vdc ) 12vdc 5.00a model numbering pm c ? 12v 060w 1 n a panel mount product type c ? enclosed output voltage output power single phase nec class 2 terminal block connector
technical d at asheet pmc panel mount power supply 12v 60w 1 phase , nec class 2 / pmc - 12v060w1na all parameters are specified at 25 c ambient unless otherwise noted. www. deltapsu .com ( june 2013 , rev. 0 0) 2 specifications input ratings / characteristics nominal input v oltage 100- 240v ac input v oltage range 85- 264vac nominal input f r equency 50- 60hz input f r equency range 47- 63hz nominal dc input voltage 125- 250 vdc dc input voltage range 125- 375vdc input cur r ent < 1.35a @ 115vac, < 0.90 a @ 230vac ef ficiency at 100% load > 8 6 .0% @ 115vac, > 8 7 .0% @ 230vac max inrush cur r ent < 50a @ 115vac, < 100a @ 230vac leakage cur r ent < 1 ma @ 240vac output ratings / characteristics nominal output voltage 12 vdc output voltage tolerance 2 % (initial set point tolerance from factory ) output voltage adjustment range 12-14 vdc output current 5 .00 a output power 60w line regulation < 0. 5 % typ. (@ 85- 264 vac input, 100% load ) load regulation < 1 % typ. ( with rated input, 0 - 100% load) pard (20mhz) < 1 00mvp p @ 25c & 50c < 150 mvpp @ -10c & -2 0 c rise time < 6 0ms @ nominal input (100% load) start - up time < 250 0ms @ nominal input (100% load) hold - up time > 15 ms @ 115vac , > 80ms @ 230vac (100% load) dynamic response (overshoot & undershoot o/p voltage) 5% @ 0 -10 0% load start - up with capacitive loads 5 ,000f max mechanical case chassis / cover aluminium dimensions (l x w x d) 128 x 97 x 38 mm unit weight 0.2 8 kg indicator green led (dc ok) cooling system convection terminal input / output 5 pins (rated 300v/ 15 a) wire input / output awg 22 -14 noise (1 meter from power supply) sound pressure level (spl) < 40dba
technical d at asheet pmc panel mount power supply 12v 60w 1 phase , nec class 2 / pmc - 12v060w1na all parameters are specified at 25 c ambient unless otherwise noted. www. deltapsu .com ( june 2013 , rev. 0 0) 3 environment surrounding air temperature operating -2 0c to + 7 0 c storage -25 c to + 85c power de - rating < -10 c de- rate power by 2.0% / c , > 50c de - rate power by 2.5% / c operating humidity < 95 % rh operating altitude 3 ,000 meters shock test (non - operating) iec 60068 -2 - 27, 3 0g (300m/s2) for a duration of 1 8 ms, 1 times per direction, 2 times in total vibration ( non - operating) iec 60068 -2 - 6, 10 hz to 15 0hz @ 50m/s2 (5g peak); 2 0 min per axis for all x, y, z direction pollution degree 2 protections overvoltage < 17.6 v , selv output, non - latching (auto - recovery) overload / overcurrent > 110-16 0% of rated load , hicc - up mode, non - latching (auto - recovery) over temperature < 7 5 c surrounding air temperature @ 100% load, non - latching (auto - recovery) short circuit hicc - up mode, non- latching (auto - recovery when the fault is removed) protection against shock class i with pe* connection *pe: primary earth reliability data mtbf > 7 00,000 hrs. as per telcordia sr - 332 expected cap life time 10 years (115vac & 230vac , 50% load @ 40c ) safety standards / directives electrical safety tuv bauart to en 60950 - 1, lps ul/cul recognized to ul 60950 -1 and csa c22.2 no. 60950 - 1, nec class 2 cb scheme to iec 60950 - 1 , lps ce in conformance with emc directive 2004/108/ec and low voltage directive 2006/95/ec material and parts rohs directive 2011/65/eu compliant galvanic isolation input to output 3 .0kvac input to ground 1.5kvac output to ground 0 .5kvac
technical d at asheet pmc panel mount power supply 12v 60w 1 phase , nec class 2 / pmc - 12v060w1na all parameters are specified at 25 c ambient unless otherwise noted. www. deltapsu .com ( june 2013 , rev. 0 0) 4 emc emc / emissions cispr 22 , en 550 22, fcc title 47 : class b (class a for dc input) immunity to en 55024 electrostatic discharge iec 61000 -4 - 2 level 4 criteria a 1) air discharge: 15kv contact discharge: 8 kv radiated field iec 61000 -4 - 3 level 3 criteria a 1) 80mhz - 1ghz, 10v/m, 80% modulation (1khz) electrical fast transient / burst iec 61000 -4 - 4 level 3 criteria a 1) 2kv surge iec 610 00 -4 - 5 level 3 criteria a 1) common mode 2) : 2 kv differential mode 3) : 2 kv conducted iec 61000 -4 - 6 level 3 criteria a 1) 150khz - 80mhz, 10vrms power frequency magnetic fields iec 61000 -4 - 8 criteria a 1) 1 0a/meter (1a/meter for dc input) voltage dips iec 61000 -4 - 11 100% dip; 1 cycle (20ms); self recoverable low energy pulse test (ring wave) iec 61000 -4 - 12 level 3 criteria a 1) common mode 2) : 2kv differential mode 3) : 1kv voltage fluctuation and flicker iec/en 61000 - 3 -3 1) criteria a: normal performance within the specification limits 2) asymmetrical: common mode (line to earth) 3) symmetrical: differential mode (line to line)
technical d at asheet pmc panel mount power supply 12v 60w 1 phase , nec class 2 / pmc - 12v060w1na all parameters are specified at 25 c ambient unless otherwise noted. www. deltapsu .com ( june 2013 , rev. 0 0) 5 block diagram device description 1 ) input & output terminal block connector 2 ) dc voltage adjustment potentiometer 3 ) dc ok control led (green)
technical d at asheet pmc panel mount power supply 12v 60w 1 phase , nec class 2 / pmc - 12v060w1na all parameters are specified at 25 c ambient unless otherwise noted. www. deltapsu .com ( june 2013 , rev. 0 0) 6 dimensions l x w x d: 1 2 8 x 97 x 38 mm engineering data de - rating note 1 . power supply components may degrade, or be damaged, when the power supply is continuously used outside the shaded region, refer to the graph shown in fig. 1. 2 . if the output capacity is not reduced when the surrounding air temperature > 50c, the device may run into over temperature protection. when activated, the output voltage will go into bouncing mode and will recover when the surrounding air temperature is l owered or the load is reduced as far as necessary to keep the device in working condition. 3 . in order for the device to function in the manner intended, it is also necessary to keep a safety distance of 20mm with adjacent units while the device is in operat ion. 4 . depending on the surrounding air temperature and output load delivered by the power supply, the device can be very hot! 5 . if the device has to be mounted in any other orientation, please do not hesitate to contact info@deltapsu.com for more details. fig. 1 de - rating for vertical and horizontal mounting orientation < -1 0c de - rate power by 2. 0 % / c > 50c de - rate power by 2.5% / c
technical d at asheet pmc panel mount power supply 12v 60w 1 phase , nec class 2 / pmc - 12v060w1na all parameters are specified at 25 c ambient unless otherwise noted. www. deltapsu .com ( june 2013 , rev. 0 0) 7 output de - rating vs. input voltage assembly & installation ? mounting holes for power supply assembly onto the mounting surface. the power supply shall be mounted on minimum 2 mounting holes using m 3 screw minimum 5 mm length. ? this surface belongs to customer?s end system or panel where the power supply is mounted. ? connector fig. 2 mounting orientation ? use flexible cable (stranded or solid) of awg no. 22-1 4 . the torque at the c onnector shall not exceed 13 kgf.cm. the insulation stripping length should not exceed 0.275? or 7mm. ? no output power de - rating across the entire input voltage range side mounting (vertical) base mounting ( vertical ) side mounting ( horizontal )
technical d at asheet pmc panel mount power supply 12v 60w 1 phase , nec class 2 / pmc - 12v060w1na all parameters are specified at 25 c ambient unless otherwise noted. www. deltapsu .com ( june 2013 , rev. 0 0) 8 installation of mounting accessories safety instructions ? to ensure sufficient convection cooling, always maintain a safety distance of 2 0mm from all ventilated surfaces while the device is in operation. ? the device is not recommended to be placed on low thermal conductive surface, for example, plastics. ? note that the enclosure of the device can become very hot depending on the ambient temperature and load of the power supply. do not touch the device while it is in operation or immediately after power is turned off. risk of burning! ? do not touch the terminals w hile power is being supplied. risk of electric shock. ? prevent any foreign metal, particles or conductors from entering the device through the openings during installation. it may cause: electric shock; safety hazard; fire; product failure ? warning: when con necting the device, secure earth connection before connecting l and n. when disconnecting the device, remove l and n connections before removing the earth connection. ? only use m 3 screw 6mm through the base mounting holes. this is to keep a safety distance between the screw and internal components . ? recommended mounting tightening torque: 4 ~ 8kgf.cm.
technical d at asheet pmc panel mount power supply 12v 60w 1 phase , nec class 2 / pmc - 12v060w1na all parameters are specified at 25 c ambient unless otherwise noted. www. deltapsu .com ( june 2013 , rev. 0 0) 9 functions start - up time the time required for the output voltage to reach 90% of its set value, after the input voltage is applied. rise time the time required for the output voltage to change from 10% to 90% of its set value. hold - up time hold up time is the time when the ac input collapses and output voltage retains regulation for a certain period of time. the time required for the output to reach 95% of its set value, after the input voltage is removed. ? graph illustrating the start - up time, rise time, and hold - up time inrush current inrush current is the peak, instan taneous, input current measured and, occurs when the input voltage is first applied. for ac input voltages, the maximum peak value of inrush current will occur during the first half cycle of the applied ac voltage. this peak value decrease s exponentially during subsequent cycles of ac voltage. dynamic response the power supply output voltage will remains within 5% of its steady state value, when su bjected to a dynamic load from 0 % to 100% of its rated current.
technical d at asheet pmc panel mount power supply 12v 60w 1 phase , nec class 2 / pmc - 12v060w1na all parameters are specified at 25 c ambient unless otherwise noted. www. deltapsu .com ( june 2013 , rev. 0 0) 10 overload & overcurrent protections the power supply?s overload (olp) and overcurrent (ocp) protections will be activated when output current exceeds 1 10- 160 % of i o (max load). in such occurrence, the v o will start to droop and once the power supply has reached its maximum power limit, the protection is activated and the power supply will go into ?hiccup mode? (auto - recovery). the power supply will recover once the fault condition of the olp and ocp is re moved and i o is back within the specifications. it is not recommended to prolong the duration of i o when it is < 1 10- 160 % but >100% , since it may cause damage to the psu. short circuit protection the power supply?s output olp/ocp function also provides protection against short circuits. when a short circuit is applied, the output current will operate in ?hiccup mode?, as shown in the illustration in the olp/ocp section on this page. the power supply will return to normal operation after the shor t circuit is removed. overvoltage protection the power supply?s overvoltage circuit will be activated when its internal feedback circuit fails. the output voltage shall not exceed its specifications defined on page 3 under ?protections?. over temperature protection as mentioned above, the power supply also has over temperature protection (otp). i n the event of a higher operating temperature at 100% load , the power supply will run into otp when the operating temperature is beyond what is recomme nded in the de - rating graph. when activated, the output voltage will go into bouncing mode until the temperature drops to its normal operating temperature as recom mended in the de - rating graph. others delta rohs compliant restriction of the usage of hazardous substances the european directive 2011/65/e u limits the maximum impurity level of homogeneous materials such as lead, mercury, cadmium, chrome, polybrominated flame retardants pbb and pbde for the use in electrical and electronic equipment. rohs is the abbreviation for ?restriction of the use of certain hazardous substances in electrical and electronic equipment?. this product conforms to this standard. conformal coating the protective coating technology delta electronics group has designed the perfect dipping technique which penetrates everywhere including under device, and prevents leakage. the conformal coating dipping can be applied to pcbs or circuit board. the coating preserves the performance of pre cision electronic primarily by preventing ionizable contaminants such as salt from reaching circuit nodes, where the material slumps around sharp edges. this can be a problem especially in highly conversing atmosphere.
mouser electronics authorized distributor click to view pricing, inventory, delivery & lifecycle information: delta: ? PMC-12V060W1NA


▲Up To Search▲   

 